orcad
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| orcad [2020/10/20 11:50] – [Behaviour] utedass | orcad [2022/09/12 00:30] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 8: | Line 8: | ||
| ===== Hotkeys ===== | ===== Hotkeys ===== | ||
| + | [[http:// | ||
| < | < | ||
| Line 36: | Line 37: | ||
| ====== Behaviour ====== | ====== Behaviour ====== | ||
| - | Connection matrix for connections with the same name. Names are not case sensitive. | + | ===== Connectivity between nets ===== |
| + | |||
| + | <color # | ||
| + | |||
| + | <color # | ||
| + | |||
| + | Connection matrix for connections with the same name. | ||
| ^ Type of connection ^ Same page ^ Same schematic ^ Same project ^ | ^ Type of connection ^ Same page ^ Same schematic ^ Same project ^ | ||
| ^ Net alias | Yes | No | No | | ^ Net alias | Yes | No | No | | ||
| Line 42: | Line 49: | ||
| ^ Hierarchical connector | Yes | Yes | No | | ^ Hierarchical connector | Yes | Yes | No | | ||
| ^ Power connector | Yes | Yes | Yes | | ^ Power connector | Yes | Yes | Yes | | ||
| + | |||
| + | Same page | ||
| + | ^ ^ Net alias ^ Off page \\ connector ^ Hierarchical \\ connector ^ Power \\ connector ^ | ||
| + | ^ Net alias | X | X | X | X | | ||
| + | ^ Off page connector | X | X | X | X | | ||
| + | ^ Hierarchical connector | X | X | X | X | | ||
| + | ^ Power connector | X | X | X | X | | ||
| + | |||
| + | Same schematic | ||
| + | ^ ^ Net alias ^ Off page \\ connector ^ Hierarchical \\ connector ^ Power \\ connector ^ | ||
| + | ^ Net alias | - | - | - | - | | ||
| + | ^ Off page connector | - | X | X | - | | ||
| + | ^ Hierarchical connector | - | X | X | - | | ||
| + | ^ Power connector | - | - | - | X | | ||
| + | |||
| + | Same project | ||
| + | ^ ^ Net alias ^ Off page \\ connector ^ Hierarchical \\ connector ^ Power \\ connector ^ | ||
| + | ^ Net alias | - | - | - | - | | ||
| + | ^ Off page connector | - | - | - | - | | ||
| + | ^ Hierarchical connector | - | - | - | - | | ||
| + | ^ Power connector | - | - | - | X | | ||
| + | |||
| + | ===== Misc ===== | ||
| Only parts from the root-schematic is exported to Layout. For ohter parts to be exported, they have to be included as hierarchical blocks in a schematic that has the root schematic as its ancestor. | Only parts from the root-schematic is exported to Layout. For ohter parts to be exported, they have to be included as hierarchical blocks in a schematic that has the root schematic as its ancestor. | ||
| + | The same name for hierarchical block instances can be used in different schematics without colliding. | ||
| + | |||
| + | Names are case insensitive regarding function. However, some functions seem to be confused by the case. For example, when having same but different cased names for hierarchical connnectors they appear as different connectors on the block, but are connected together anyway. | ||
| + | |||
| + | A hierarchical block always lead to the oldest page in that schematic when descending the block. | ||
| + | |||
| + | Thermal reliefs are not generated on pads that are smaller than the thermal relief width. That is, pads that have one dimension that is smaller than the " | ||
orcad.1603194634.txt.gz · Last modified: 2022/09/12 00:30 (external edit)
